Safety relays for E/Stop applications

SRB 220XV2

Features:
Suitable for signal processing of alternatively:
– Potential-free outputs, e.g. emergency-stop command devices, interlocking equipment etc.
– Restrictedly suitable for signal processing (no reset with edge detection) of outputs connected to potentials (AOPD's), e.g. safety light grids / curtains
1 or 2 channel control
2 enabling paths, Stop 0; 2 enabling paths, Stop 1
Switching capacity of the enabling contacts: 8 A
Manual reset with edge detection in fail-safe circuit
Automatic reset function
Optionally cross-wire monitoring
Green LED indications for relay K1, K2, supply voltage UB and internal fuse Ui
Control Category 4 to EN 954-1
Further technical data and the wiring diagram you'll find in the datasheet by using the pdf-button.

SRB 220XV2